jun 20, 2006 revised to jul 21, 2006 page 1 of 4 www.power-one.com m series data sheet 50-watt ac-dc cassette converters ? rohs lead-solder-exempt compliant 1 ? rugged electrical and mechanical design ? outputs individually controlled with excellent dynamic properties ? operating ambient temperature range of ?40 to 71 c with convection cooling features the m series of ac-dc cassettes represents a broad and flexible range of power supplies for use in advanced industrial electron ic systems. features include high efficiency, reliability, low output voltage noise, and excellent dynamic response to load/line ch anges due to individual regulation of each output. description output 1 output 2 output 3 nom. input model options v o nom i o nom v o nom i o nom v o nom i o nom voltage [vdc] [a] [vdc] [a] [vdc] [a] vi [vac] 5.1 8 - - - - 100 - 240 lm1001-7r -9, e, p, d, v, a, f 12 4 - - - - 100 - 240 lm1301-7r -9, e, p, d, a, f 15 3.4 - - - - 100 - 240 lm1501-7r -9, e, p, d, a, f 24 2 - - - - 100 - 240 lm1601-7r -9, e, p, d, a, f 48 1 - - - - 100 - 240 lm1901-7r -9, e, p, d, a, f 12 2 12 2 - - 100 - 240 LM2320-7 -9, e, p, d, a, f 15 1.7 15 1.7 - - 100 - 240 lm2540-7 -9, e, p, d, a, f 5.1 5 12 0.7 12 0.7 100 - 240 lm3020-7 -9, e, p, d, v, a, f 5.1 5 15 0.6 15 0.6 100 - 240 lm3040-7 -9, e, p, d, v, a, f model selection 1 the solder exemption refers to all the restricted materials except lead in solder.
m series data sheet 50-watt ac-dc cassette converters jun 20, 2006 revised to jul 21, 2006 page 2 of 4 www.power-one.com input nom. voltage and frequency continuous range 100 - 240 vac, 50 - 60, 440 hz operating voltage and frequency continuous range 85 - 264 vac, 47 - 440 hz inrush current limitation by thermistor output efficiency v i nom , i o nom up to 81% output voltage setting accuracy v i nom , i o nom better than 1% v o nom output voltage switching noise iec/en 61204, total typ. 50 mvpp line regulation v i min - v i max , i o nom , each output regulated typ. 0.2% v o nom load regulation v i nom , 0 - i o nom , each output regulated typ. 0.15% v o nom minimum load not required 0 a current limitation main output rectangular v/i characteristic typ. 110% i o nom current limitation aux. output(s) rectangular v/i characteristic typ. 120% i o nom operation in parallel by current limitation, only main outputs hold-up time vi = 230 v ac, i o nom typ. 90 ms protection input fuse built-in t 2.5 a, 250 v ac input undervoltage lockout typ. 80% vi min input overvoltage lockout typ. 110% vi max input transient protection varistor or suppressor diode output no-load, overload, and short-circuit proof output overvoltage suppressor diode in each output typ. 150% vo nom overtemperature protection switch-off with auto restart tc typ. 100 c control output voltage adjustment single output types 0 - 110% vo1 nom inhibit ttl input, output(s) disabled if open circuit status indication 3 leds: ok, inhibit, overload safety approvals en 60950, ul 1950, csac22.2 no. 950 class i equipment protection degree units without options ip 40 electric strength test voltage input against (case + outputs) 2 kv ac
pin electrical determination lm1000 lm2000 lm3000 2 inhibit control input i i i 5 data safe or acfail d or v d or v d or v 8 output positive vo+ vo3+ 11 output negative vo? vo3? 14 control input + r 17 control input ? g 14 output positive vo2+ vo2+ 17 output negative vo2? vo2? 20 output positive vo+ vo1+ vo1+ 23 output negative vo? vo1? vo1? 26 protective earth pe 29 ac input neutral n n n 32 ac input phase l l l jun 20, 2006 revised to jul 21, 2006 page 3 of 4 www.power-one.com m series data sheet 50-watt ac-dc cassette converters emc electrostatic discharge iec/en 61000-4-2, level 4 (8/15 kv) criterion a electromagnetic field iec/en 61000-4-3, level x (20 v/m) criterion a/b electr. fast transients/bursts iec/en 61000-4-4, input, level 3/4 (2/4 kv) criterion a/b surge iec/en 61000-4-5, input, level 3/4 (2/4 kv) criterion a conducted disturbances iec/en 61000-4-6, level 3 (10 v) criterion b electromagnetic emissions cispr 22/en 55022, class i, conducted class b environmental operating ambient temperature vi nom, io nom, convection cooled ?25 to 71 c operating case temperature tc vi nom, io nom ?25 to 95 c storage temperature non operational ?40 to 100 c damp heat iec/en 60068-2-78, 93%, 40 c 56 days vibration, sinusoidal iec/en 60068-2-6, 10 - 60/60 - 2000 hz 0.35 mm/5 g n shock iec/en 60068-2-27, 6 ms 100 g n bump iec/en 60068-2-29, 6 ms 40 g n random vibration iec/en 60068-2-64, 20 to 500 hz 4.9 g n rms mtbf mil-hdbk-217e, gb, 40 c, single output models 320 000 h options extended temperature range ?40 to 71 c, ambient, operating -9 electronic inrush current limitation e output voltage adjustment 95 - 105% vo nom, excludes feature r p input and/or output undervoltage monitoring, excludes option v d0 - d9 input and/or output undervoltage monitoring (vme), excludes option d v1 - v3 test sockets for check of output voltage a fuse not user-accessible f pin allocation
m series data sheet 50-watt ac-dc cassette converters jun 20, 2006 revised to jul 21, 2006 page 4 of 4 www.power-one.com mechanical data 111.2 (3u) 88 (11.6) 168.5 127 173.7 20 100 1.6 6te 2 5 8 11 14 17 20 23 26 29 32 male connector h11 accordin g to din 41 612 (gold plated contacts on customer's request) 38.7 95 measurin g point for case temperature t c m 3; depth = 4 mm (chassis mount) 22 68 159.4 mountin g plane of connector h11 5.08 10.16 15.24 20.32 25.40 30.48 2te 7.09 17.25 28.6 34 15 4 mountin g holes for retainin g clips (hzz01209) 12.17 103 3.27 20.5 12.1 94.5 0 31.5 0 ? 3.5 ? 4.0 i ol (led red) test sockets (option a) potentiometer(s) (option p) ok (led g reen) inhibit i (led red) front plate main face rear face back plate 22.30 09012 potentiometer (option d or v) nuclear and medical applications - power-one products are not designed, intended for use in, or authorized for use as critical c omponents in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written conse nt of the respective divisional president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. specifications are subject to change without notice. dimensions in mm. the power supplies are designed to be inserted into a 19? rack, 160 mm long, according to iec 60297-3. european projection accessories front panels 19? (schroff/intermas) mating h11 connectors with screw, solder, fast-on or press-fit terminals connector retention facilities and code key system for connector coding flexible pcb for connecting the converter via an h11 connector, if mounted on a pcb chassis or wall mounting plates for frontal access universal mounting brackets for chassis or din-rail mounting
|